Model Description
120ADP For ease of monitoring single-phase loads. Adapter is plugged into standard grounded 120 V outlet, unit under test is plugged into Adapter. Voltage and current sense outputs plug directly into PowerSight.
120ADPA
120 Volt Output Test Adapter for monitoring single-phase loads. Adapter is plugged into standard grounded 120 V outlet, unit under test is plugged into Adapter. Voltage and current sense outputs plug directly into PowerSight.
15KVP
15KV voltage probe for direct connection to 600 to 15kv rms AC or DC. Ground lead and 1.3 hook tip included. 16 long and 1.5 in Diameter. Hot stick attachment is needed.
15KVPSet
Set of 3 15KV voltage probes with hot sticks for direct connection to 600 to 15kv rms AC or DC. Ground lead and 1.3 hook tip included. 16 long and 1.5 in Diameter.
5KVP
5KV voltage probe for direct connection to 600 to 5kv rms AC or DC. Ground lead and hook tips included. Suitable for direct harmonic analysis of higher voltages.
5KVPSet Set of three 5KV-voltage probes for direct connection to 600 to 5kv rms AC or DC. Ground lead and hook tips included. Suitable for direct harmonic analysis of higher voltages.
BTA Bluetooth Adapter for USB, with software
CALCERT Calibration Certificate, under warranty
CALIB Calibration of meter that is out of warranty
CAS3
Hard Shell Carrying Case Molded plastic case with positive locking latches. Foam insert has cutouts for PowerSight and its accessories. Black with carrying handle. Outside dimensions: 19 x 16 x 7 inches.
CASA Hard Shell Carrying Case Molded plastic case with positive locking latches. Foam insert has cutouts for PowerSight and its accessories. Black with carrying handle. Outside dimensions: 13.5 x 9 x 5.5 inches.
CASW
Weather-Resistant Operating CaseMolded plastic case with positive locking latches. Foam insert has cutouts for PowerSight and a sealing channel for lead access. Black with carrying handle. Lockable. The Line to DC Converter [LDC] can be installed in the Case to power the PowerSight unit. Outside dimensions: 16 x 13 x 7 inches.
CBL2M 2 meter 4 wire cable replacement, with machined collar as requred
CHG1
Plugs into standard European 50Hz outlet to supply 12VDC @ 500ma. For all meters excpet PowerSight PS3000
CHG2
Plugs into standard European 50Hz outlet to supply 12VDC for PowerSight. PS3000
CHG3
Plugs into standard North American 60Hz outlet to supply 12VDC for PowerSight. PS3000
CHG4
Plugs into standard North American 60Hz outlet to supply 12VDC @ 500ma. For all meters except PowerSight PS3000
COMM
RS232 cable for communications to PowerSight models PS250/3000/4000
CT1000S5K 1,000A 5KV split-core CT for SafeConnect
CT1000T5K 1,000A 5KV toroid CT for SafeConnect
CT1000T600 1,000A 600 toroid CT for SafeConnect
CT100S5K 100A 5KV split-core CT for SafeConnect
CT100T5K 100A 5KV toroid CT for SafeConnect
CT100T600 100A 600 toroid CT for SafeConnect
CT5T600 5A 600 toroid CT for SafeConnect
DC600
DC/AC 600/400 amp Probe 5 to 400 amps AC/DC, 400 to 600 amps DC. 2%+/-2LSDs to 400 amps. 3%+/-2LSDs to 600 amps. Inside diameter one 1.18 cable or two 0.95 cables. Outside dimentions 7.68 x 2.6 x 1.34 inch.
DFV
Deluxe Fused Voltage Lead Set Set of 4 color coded barrel fused safety leads, 7 feet long, with telescoping jaws to grab bolts up to in diameter. Each probe contains a 1000V fuse.
DFVupg Fused leads to insert into DXV set to make them DFV
DXV
Set of 4 color coded safety leads, 7 feet long, with telescoping jaws to grab bolts up to in diameter.
DXV25 25 foot DXV Lead Set
DXV25upg DXV25 upgrade from DXV
eFX6000 Flexible 6000 amp Probe. 1 to 6000 amps AC. 3%+/-2LSDs. Inside diameter 7.5 inch (190mm). Circumference 24 inches (610mm). Dimensions flexible tube of 24" x .375" (0.5" max.)
eFX6000-36 Flexible 6000 amp Probe. 1 to 6000 amps AC. 3%+/-2LSDs. Inside diameter 11.5 inch (290mm). Circumference 36 inches (910mm). Dimensions flexible tube of 24" x .375" (0.5" max)
FAO
Frequency Analysis Option Power-line spectrum analysis from 3kHz to 100kHz, detecting 0.1mVrms to 1Vrms
FW2.0/1/2/3/4 FW upgrade from 2.0/1/2/3/4 to 2.9
FW2.5 FW upgrade from 2.5 to 2.9
FW2.6/7/8 FW upgrade from 2.6/7/8 to 2.9
FX3000
Flexible 3000 amp Probe. 10 to 3000 amps AC. 3%+/-2LSDs. Inside diameter 7.5 inch (190mm). Circumference 24 inches (610mm). Dimensions flexible tube of 24" x .85" (1.0" max.)
FX3000-36 Flexible 3000 amp Probe, 36 inch long
FX5000
100 to 5000 amps AC. 3%+/-2LSDs. Inside diameter 7.5 inch (190mm). Circumference 24 inches (610mm). Dimensions flexible tube of 24.0 x .85 inch.
FX-HEAD Flex-Head replacement
HA100
*Clearance* Clamp-on 100 amp Probe0.1 to 100 Arms AC. 2% +/- 2LSDs. Inside diameter of 0.8 (20mm). Outside dimensions of 5.25 x 2.06 x 1.35
HA1000
Clamp-on 1000 amp Probe 1 to 1000 amps AC. 0.5%+/-2LSDs. Inside diameter 2.17 inch (55mm). Outside dimensions 8.1 x 4.1 x 1.54 inch.
HA3000
5 to 3000 amps AC. +/- 1.5 amps plus 0.5 % of reading. Inside openning 2.5 inch diameter, or 1.97x 5.31 inches or 2.56 x 3.94 inches for bus bars. Outside dimensions 12.4 x 4.72 x 1.54 inch.
HA5
Clamp-on 5 amp Probe 0.02 to 5 Arms AC. 2% +/- 2LSDs. Inside diameter of 0.8" (20mm). Outside dimensions of 5.25 x 2.06 x 1.35"
HA500 Clamp-on 500 amp Probe
HA-GFD
5ma to 1 amps AC 1% +/- 2ma and 1 to 200 amps AC 1% +/-0.2A, 4.5" inside openning
HAO
Harmonics analysis option for PS250
HW5 PS250/3000 new HW5 electronics
InLineFuse In-Line Fuse Assembly including housing and fuse, red or black
LDC2
Line-to-DC Converter for PS250 Converts any line power of 120 to 600V to +12VDC @ 100ma with barrel plug output to power PowerSight PS250 from voltage under test. Combines with battery backup to ensure self-power for months at a time. Includes fused voltage probes.
LDC3
Converts any line power of 120 to 600V to +12VDC @ 100ma with pin plug output to power PowerSight PS3000 from voltage under test. Combines with battery backup to ensure self-power for months at a time. Includes fused voltage probes.
LDC4
Line-to-DC Converter converts any line power of 120 to 600V to +12VDC @ 500ma with barrel plug output to power PowerSight from voltage under test. Combines with battery backup to ensure self-power for months at a time. Includes fused voltage probes. For all meters except PS3000
LOG
Man250 Printed manual for the PS250
Man2500 Printed manual for the PS2500
Man3000 Printed manual for the PS3000
Man3500 Printed manual for the PS3500
Man4000 Printed manual for the PS4000 and PSM3.0
Man4500 Printed manual for the PS4500
MEM
4Mb of RAM, internal
MEM1
16Mb of RAM, internal
MEM2
16Mb of RAM, internal
NET-RS232
Ethernet to RS232 Converter Adapter and software for Ethernet connection for PowerSight PS250/3000/4000
PCCA
PC Control/Analysis Option - Included with PS250, PS3000 & PS4000
PDA Personal Digital Assistant for running PSM-Mobile
PDA-Set Personal Digital Assistant with PSM-Mobile loaded
PK213
System includes: PS250 with three (3) HA1000 Current Probes, DXV Voltage Leads, SCAS4 Soft Case, 120 Volt DC Charging Unit, serial comm cable, and Operating Manual
PK214
System includes: PS250 with four (4) HA1000 Current Probes, DXV Voltage Leads, SCAS4 Soft Case, 120 Volt DC Charging Unit, serial comm cable, and Operating Manual
PK233
System includes: PS250 with three (3) FX3000 Current Probes, DXV Voltage Leads, SCAS4 Soft Case, 120 Volt DC Charging Unit, serial comm cable, and Operating Manual
PK234
System includes: PS250 with four (4) FX3000 Current Probes, DXV Voltage Leads, SCAS4 Soft Case, 120 Volt DC Charging Unit, serial comm cable, and Operating Manual
PK2513
System includes: PS2500 with SCAS4 Soft Case, three (3) HA1000 Current Probes, DXV Voltage Leads, 120 Volt DC Charging Unit, and Operating Manual
PK2514
System includes: PS2500 with SCAS4 Soft Case, four (4) HA1000 Current Probes, DXV Voltage Leads, 120 Volt DC Charging Unit, and Operating Manual
PK2533
PS2500 with three (3) FX3000 Flexible Current Probes, in SCAS4 soft case.
PK2534
System includes: PS2500 with SCAS4 Soft Case, four (4) FX3000 Current Probes, DXV Voltage Leads, 120 Volt DC Charging Unit, and Operating Manual
PK2563 PS2500 system with 3 eFX6000 amp probes
PK2564 PS2500 system with 4 eFX6000 amp probes
PK3014 System includes PS3000 with four (4) HA100 Current Probes, DXV Voltage Leads, CAS3 Hard-Shell Carrying Case, 120 Volt DC Charging Unit, serial comm cable, and Operating Manual.
PK3054 System includes PS3000 with four (4) HA5 Current Probes, DXV Voltage Leads, CAS3 Hard-Shell Carrying Case, 120 Volt DC Charging Unit, serial comm cable, and Operating Manual.
PK313
System includes: PS3000 with three (3) HA1000 Current Probes, DXV Voltage Leads, 120 Volt DC Charging Unit, serial comm cable, and Operating Manual
PK314
System includes: PS3000 with four (4) HA1000 Current Probes, DXV Voltage Leads, CAS3 Hard-Shell Carrying Case, 120 Volt DC Charging Unit, serial comm cable, and Operating Manual
PK333
System includes: PS3000 with three (3) FX3000 Current Probes, DXV Voltage Leads, CAS3 Hard-Shell Carrying Case, 120 Volt DC Charging Unit, serial comm cable, and Operating Manual
PK334
System includes PS3000 with four (4) FX3000 Flexible Current Probes, DXV Voltage Leads, CAS3 Hard-Shell Carrying Case, 120 Volt DC Charging Unit, serial comm cable, and Operating Manual.
PK35014 PS3500 system with 4 100 amp Probes
PK3513 System includes: PS2500 with SCAS4 Soft Case, three (3) HA1000 Current Probes, DXV Voltage Leads, 120 Volt DC Charging Unit, and Operating Manual
PK3514
System includes: PS3500 with four (4) HA1000 Current Probes, DXV Voltage Leads, CAS3 Hard-Shell Carrying Case, 120 Volt Charging Unit, and Operating Manual.
PK3533 PS3500 with three (3) FX3000 Flexible Current Probes, in CAS3 hard shell carry case.
PK3534
System includes: PS3500 with four (4) FX3000 Current Probes, DXV Voltage Leads, CAS3 Hard-Shell Carrying Case, 120 Volt Charging Unit, and Operating Manual.
PK354 System includes PS3000 with four (4) FX5000 Flexible Current Probes, DXV Voltage Leads, CAS3 Hard-Shell Carrying Case, 120 Volt DC Charging Unit, serial comm cable, and Operating Manual.
PK3554 PS3500 with four (4) FX5000 Flexible Current Probes, in CAS3 hard shell carry case.
PK3563 PS3500 system with 3 eFX6000 amp probes
PK3564
PS3500 system with 4 eFX6000 amp probes
PK413
System includes: PS4000 with three (3) HA1000 Current Probes, DXV Voltage Leads, CAS3 Hard-Shell Carrying Case, 120 Volt Charging Unit, serial comm cable, and Operating Manual.
PK414
System includes: PS4000 with four (4) HA1000 Current Probes, DXV Voltage Leads, CAS3 Hard-Shell Carrying Case, 120 Volt Charging Unit, serial comm cable, and Operating Manual.
PK433
PS4000 with three (3) FX3000 Flexible Current Probes, in CAS3 hard shell carry case.
PK434
System includes PS4000 with four (4) FX3000 Flexible Current Probes, DXV Voltage Leads, CAS3 Hard-Shell Carrying Case, 120 Volt Charging Unit, serial comm cable, and Operating Manual.
PK45014
System includes: PS4500 with four (4) HA100 Current Probes, DXV Voltage Leads, CAS3 Hard-Shell Carrying Case, 120 Volt Charging Unit, and Operating Manual.
PK45054 System includes: PS4500 with four (4) HA5 Current Probes, DXV Voltage Leads, CAS3 Hard-Shell Carrying Case, 120 Volt Charging Unit, and Operating Manual.
PK4514
System includes: PS4500 with four (4) HA1000 Current Probes, DXV Voltage Leads, CAS3 Hard-Shell Carrying Case, 120 Volt Charging Unit, and Operating Manual.
PK4534
System includes: PS4500 with four (4) FX3000 Current Probes, DXV Voltage Leads, CAS3 Hard-Shell Carrying Case, 120 Volt Charging Unit, and Operating Manual.
PK454 PS4000 with four (4) FX5000 Flexible Current Probes, in CAS3 hard shell carry case.
PK4554
PS4500 with four (4) FX5000 Flexible Current Probes, in CAS3 hard shell carry case.
PK4563
PS4500 system with 3 eFX6000 amp probes
PK4564
PS4500 system with 4 eFX6000 amp probes
PlnBlk Black repacement plunger clamp with telescoping jaws for the DXV.
PlnRed Red repacement plunger clamp with telescoping jaws for the DXV.
PROBEXT Current Probe extension cable
PS250
PS250 comes equipped with Deluxe Voltage leads, PowerSight Manager Software, AC-to-DC charging unit, soft carrying case, and operating manual. Communications are via RS232 technology. Just add current probes to have a complete system.
PS2500
PS2500 comes equipped with Deluxe Voltage leads, PowerSight Manager Software, AC-to-DC charging unit, soft carrying case, and operating manual. Communications are via Bluetooth technology. Just add current probes to have a complete system.
PS3000
Measure voltage, current, power, energy, cost, power factor, THD (total harmonic distortion), transients, frequency, duty cycle, and power cycles on three phase and single phase circuits. Compute present, minimum, maximum and average value each second for seven inputs (three voltages and four currents). Capture waveforms. Includes internal rechargeable batteries and wall mount power supply/charger.
PS3500
PS3500 comes equipped with Deluxe Voltage leads, PowerSight Manager Software, AC-to-DC charging unit, and operating manual. Communications are via Bluetooth technology.
PS4000
PS4000 comes equipped with Harmonics capability, Datalogging capability, Deluxe Voltage leads, PowerSight Manager Software, AC to DC charging unit and operating manual. Just add current probes and the carrying case of your choice to have a complete system. - Discontinued - replaced by Summit Technology PS4500
PS4500
Power Monitor - Powerhouse PS4500
PS-CD CD-ROM containing software, firmware, manual, application notes, product descriptions, sample data
PSM
PowerSight Manager Software - Included with PS250, PS3000 & PS4000
PSM-Mobile PowerSight Manager software for Windows Mobile operating system
RWAR1
RWAR1 reinstates deluxe warranty for 12 months. Reinstated deluxe warranty includes free software and firmware upgrades for 1 year after purchase, one free calibration per year if needed, and repair of equipment and accessories due to reasonable wear and tear.
RWAR2
RWAR2 reinstates deluxe warranty for 24 months. Reinstated deluxe warranty includes free software and firmware upgrades for 2 years after purchase, one free calibration per year if needed, and repair of equipment and accessories due to reasonable wear and tear.
RWAR41
RWAR41 reinstates deluxe warranty for 12 months. Reinstated deluxe warranty includes free software and firmware upgrades for 1 year after purchase, one free calibration per year if needed, and repair of equipment and accessories due to reasonable wear and tear.
RWAR42
RWAR42 reinstates deluxe warranty for 24 months. Reinstated deluxe warranty includes free software and firmware upgrades for 2 years after purchase, one free calibration per year if needed, and repair of equipment and accessories due to reasonable wear and tear.
RWAR43 RWAR43 reinstates deluxe warranty for 36 months. Reinstated deluxe warranty includes free software and firmware upgrades for 3 years after purchase, one free calibration per year if needed, and repair of equipment and accessories due to reasonable wear and tear.
SAFEA SafeConnect Adapter for connecting PowerSight.
SAFEA-N SafeConnect Adapter with Neutral for connecting PowerSight.
SAFEC SafeConnect System (call for CT options, base price listed).
SAFEC-N SafeConnect System with Neutral (call for CT options, base price listed).
SCAS2
Cordura case to hold PowerSight. The PS3000 can be operated while in its protective case by pressing buttons and viewing the display through its clear plastic cover. A stiff flap protects this cover when not viewing the PS3000. The PowerSight case has shoulder strap with a loop that the unit can hang from while monitoring.
SCAS3
Cordura case to hold accessories like probes, cables, and manuals. Shoulder strap included. Outside dimensions: 8 x 8 x 5 inches.
SCAS4
Cordura case to hold meter and all accessories like probes, cables, and manuals. Shoulder strap included. Outside dimensions: 9 x 5.5 x 7 inches.
SD256M SD Memory card, 256Mbyte
STKS Hot sticks for use with the 15KVP. One set of sticks required for each 15KVP
TH-USB Temperature Humidity Logger
USB-RS232
USB to RS-232 Converter for PowerSight PS250/3000/4000
VJClip Set of 4 jumbo alligator clips, open to 1.26", 600V CAT IV
VxCombo Replacement of one of the DXV leads.with plunger clamp attached.
VxLead Replacement voltage lead for use with DXV or FXV
WAR1
Normal deluxe warranty is for 12 months. WAR1 adds 12 additional months. Extended deluxe warranty includes free software and firmware upgrades for 2 years after purchase, one free calibration per year if needed, and repair of equipment and accessories due to reasonable wear and tear.
WAR2
Normal deluxe warranty is for 12 months. WAR2 adds 24 additional months. Extended deluxe warranty includes free software and firmware upgrades for 3 years after purchase, one free calibration per year if needed, and repair of equipment and accessories due to reasonable wear and tear.
WAR41
Normal deluxe warranty is for 12 months. WAR41 adds 12 additional months. Extended deluxe warranty includes free software and firmware upgrades for 2 years after purchase, one free calibration per year if needed, and repair of equipment and accessories due to reasonable wear and tear.
WAR42
Normal deluxe warranty is for 12 months. WAR41 adds 24 additional months. Extended deluxe warranty includes free software and firmware upgrades for 2 years after purchase, one free calibration per year if needed, and repair of equipment and accessories due to reasonable wear and tear.
WARMA1 Service contract on AMD for software upgrades for 1 year
WARMA2 Service contract on AMD for software upgrades for 2 year
|