±50 mV, ±500 mV, ±5 V, ±50 V, 0-100 mV, 0-1 V, 0-10 V, 0-100 V, 0-20 mA |
±50 mV, ±500 mV, ±5 V, 0-100 mV, 0-1 V, 0-10 V, 0-100 V, 0-20 mA |
±50 mV, 0-100 mV, ±5 V, 0-10 V, 0-20 mA or 4-20 mA |
Operating Modes |
Handbook 44 Certified Class III, IIIL, IV High performance scale meter, 5-point linearization, sequential tare |
High performance - Strain meter Microvolt meter |
Strain meter On/off control Alarm monitor |
Model |
INFP |
INFCP |
IDP |
Communications |
Isolated RS-232, RS-485/RS-422, BCD |
None |
None |
Excitation |
10 Vdc @ 30 mA, 24 Vdc @ 25 mA |
24 Vdc @ 25 mA,12 Vdc @ 50 mA, 10 Vdc @ 120 mA, 5 Vdc @ 60 mA |
10 Vdc @ 50 mA24 Vdc @ 25 mA |
Output |
4 open-collectors 30 V/1 V @ 150 mA Dual 7-amp relays 4 Relays, 2 ea. 7A & 1A 4-20 mA or 0-10 V Analog |
Dual 6-amp relays Analog Output 4-20 mA Analog Output 0-10 Vdc |
None |
Accuracy |
±0.005% |
±0.03%R ±50 ppm /°C |
±0.05%R±1 lsd |
Display |
6-Digit, 14-Segment, Red or Green LED, Alphanumeric |
4-Digit, 14-Segment, Red or Green LED, Alphanumeric |
4-Digit, 7-Segment, Red or Green LED |
Input |
4-20 mA (5ohms), ±50 mV 0-100 mV, ±500 mV 0-1.00V, ±5.00V 0-10.0V, ±50.0V 0-100V |
4-20 mA (5 ohms) ±50, 0-100 mVdc ±5, 0-10 Vdc |
4-20 mA (20 ohm) 0-5 Vdc, 1-5 Vdc 0-10 Vdc |
Operating Modes |
Process meter On/off control Proportional control (optional) Alarm monitor |
Process meter On/off control Alarm monitor |
1/4 DIN Process meter |
Model |
205/305E |
508/558B |
DP1028 |
Communications |
None |
None |
None |
Excitation |
10 Vdc @ 30 mA to 24 Vdc @ 20 mA |
N/A |
N/A |
Output |
None |
None |
None |
Accuracy |
±0.05%R±1 lsd |
±0.1%R±1 lsd |
±1 count over entire range |
Display |
3 1Ž2-Digit, 7-Segment, Red or Green LED |
3 1/2-Digit, 7-Segment LCD |
4 1/2 digits 0.6" (15 mm) high |
Input |
4-20 mA (13 ohm) 0-200 mVdc, 1-5 Vdc 0-10 Vdc, 0-100 Vdc |
1-5 mA, 4-20 mA, 10-50 mA (125 ohms @ 20 mA) (625 ohms @ 4 mA) |
Switch Selectable |
Operating Modes |
3/64 DIN Process meter |
Loop-powered indicator |
Transducer Indicator System |